Med. praxi. 2012;9(5):222-226

Self-monitoring of blood glucose

MUDr.Tomáš Edelsberger
Privátní diabetologická ambulance Krnov

Self-monitoring of blood glucose is nowadays an integral part of beeing of diabetic patients. An active complicity of a patient with diabetes

on a control and therapy of the disease belongs to complex diabetes care. Every diabetic patient shloud get an adequate knowledge

about principles of the disease needed to perform lifestyle and therapeutical decisions within self-management of his diabetes. Selfmonitoring

of blood glucose for patients with type 1 diabetes and for those with type 2 diabetes treated with insulin is beneficial in

prevention of acute and chronic vascular complications.

Keywords: self-monitoring of blood glucose, diabetes mellitus, education, vascular complications, hypoglycaemia

Published: May 31, 2012  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Edelsberger T. Self-monitoring of blood glucose. Med. praxi. 2012;9(5):222-226.
Download citation

References

  1. Barnett AH, Krentz AJ, Strojek K, et al. The efficacy of selfmonitoring of blood glucose in the management of patients with type 2 diabetes treated with a gliclazide modified release-based regimen. A multicentre, randomized, parallel-group, 6-month evaluation (DINAMIC 1 study). Diabetes Obes Metab. 2008; 10: 1239-1247. Go to original source... Go to PubMed...
  2. Breton MD, Kovatchev BP. Impact of blood glucose self-monitoring errors on glucose variability, risk for hypoglycemia, and average glucose control in type 1 diabetes: an in silico study. J Diabetes Sci Technol. 2010; 4(3): 562-570. Go to original source... Go to PubMed...
  3. Brož J. Současné možnosti monitorování glykémie. Remedia, 2/2006.
  4. Brož J. Kontinuální monitoring glykémie: přehled přístrojů, indikace, efektivita a přesnost metody In Technologie v diabetologii 2010. Praha: Galén, 2010. Kapitola 11, s. 142-152.
  5. Číselník VZP: ZP Metodika, Verze 830. www.vzp.cz.
  6. Doporučený postup České diabetologické společnosti: Selfmonitoring glykémie v lékárně, www.diab.cz.
  7. Guideline on Self-Monitoring of Blood Glucose in Non-Insulin Treated Type 2 Diabetes, www.idf.org.
  8. Honka M. Selfmonitoring v roce 2010. In Technologie v diabetologii 2010. Praha: Galén, 2010. Kapitola 20, s. 262-281.
  9. http://en.wikipedia.org/wiki/Glucose_meter.
  10. http://www.glucosemetercomparison.com.
  11. http://www.rok1.cz/spravne-mereni-glykemie/spravnemereni-glykemie-3/.
  12. http://www.zdn.cz/clanek/priloha-pacientske-listy/selfmonitoring-zmerte-si-cukr-doma-451059.
  13. Kvapil M. Selfmonitoring glykémie u pacientů s diabetem 2. typu: diabetes se sám od sebe nevyléčí. Medical Tribune 14/2011.
  14. McAndrew L, Schneider SH, Burns E, et al. Does patient blood glucose monitoring improve diabetes control? A systematic review of the literature. Diabetes Educ. 2007; 33: 991-1011. Go to original source... Go to PubMed...
  15. Parkes JL, Slatin SL, Pardo S, Ginsberg BH. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care. 2000; 23(8): 1143-1148. Go to original source... Go to PubMed...
  16. Poolsup N, Suksomboon N, Jiamsathit W. Systematic review of the benefits of self- monitoring of blood glucose on glycemic control in type 2 diabetes patients. Diabetes Technol Ther. 2008; 10(Suppl 1): S-51-S-66. Go to original source...
  17. Standards of Medical Care in Diabetes 2012. Diabetes Care, 2012; 35(Suppl 1).
  18. Stanovisko České diabetologické společnosti: Materiální zajištění pro sebekontrolování hladin krevního cukru u nemocných cukrovkou, www.diab.cz.
  19. Szymborska-Kajanek A, Psurek A, Hese R, Strojek K. Selfmonitoring of blood glucose in treatment of type 2 diabetes. Diabetes Res Clin Pract. 2009; 86(Suppl 1): S49-52. Go to original source... Go to PubMed...
  20. Towfigh A, Romanova M, Weinreb JE, et al. Self-monitoring of blood glucose levels in patients with type 2 diabetes mellitus not taking insulin: a meta-analysis. Am J Manag Care. 2008; 14: 468-475.
  21. http://diafarm.cz/index.php/public/category/id/5.
  22. Freckmann G, Baumstark A, Jendrike N, Zschornack E, Kocher S, Tshiananga J, Heister F, Haug C. System accuracy evaluation of 27 blood glucose monitoring systems according to DIN EN ISO 151 97. Diabetes Technol Ther. 2010; 12(3): 221-231. Go to original source... Go to PubMed...
  23. Sacks DB, Arnold M, Bakris GL, Bruns DE, Horvath AR, Kirkman MS, Lernmark A, Metzger BE, Nathan DM. Executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem. 2011; 57(6): 793-798. Epub 2011 May 26. Go to original source... Go to PubMed...
  24. Diabetes mellitus - laboratorní diagnostika a sledování stavu pacientů.




Medicine for Practice

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.